HPE / ProLiant: OID-Referenz
172 OIDs der Gruppe HPE / ProLiant mit Name und MIB-Beschreibung, wie sie SNMP Explorer für Mac von Haus aus kennt.
All HPE
1.3.6.1.4.1.232
All HPE/Compaq Insight Management MIBs: full hardware health, inventory, performance
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqStdEqComponent | HPE CPQSTDEQ-MIB root. Standard equipment MIB covering processors, memory, expansion slots, and other standard server components. |
| 1 | cpqStdEqObjects | Standard equipment object group containing processor, memory, and expansion slot tables. |
System Info
1.3.6.1.4.1.232.2
CPQSINFO: server model, serial number, ROM version, UUID, POST status
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqSiComponent | HPE CPQSINFO-MIB root. Contains server identification, product name, serial number, ROM version, memory, and asset information. |
| 1 | cpqSiHardwareMgmtRevMajor | Major revision number of the HPE Hardware Management (Insight Management Agents) software installed on this server. |
| 1 | cpqSiHardwareMgmtRevMinor | Minor revision number of the HPE Hardware Management (Insight Management Agents) software installed on this server. |
| 1 | cpqSiHardwareMgmtRevDev | Development or build version of the HPE Hardware Management software. Combined with Major/Minor gives full version e.g. 1.39.2. |
| 1 | cpqSiSysTable | System identification table: serial number, NIC count, product ID, and other server-level identifiers. |
| 1 | cpqSiSysSerNum | The system serial number (service tag) assigned by HPE during manufacturing. Used for warranty lookup and support identification. |
| 1 | cpqSiSysNicCount | The total number of Network Interface Controllers (NICs) physically installed in this server, including embedded and add-in NICs. |
| 1 | cpqSiSysAssets | Asset identification string for this server. May contain customer-defined asset tag or location data. |
| 1 | cpqSiMemTotalSlots | Total number of physical memory module (DIMM) slots available in this server chassis. |
| 1 | cpqSiSysProductID | HPE product ID / part number for this server (e.g. 843556-425). Used to identify the specific server model and configuration. |
| 1 | cpqSiMemModuleTable | Memory module table. Each entry describes one DIMM slot: size in KB, speed in MHz, type (DDR4 etc.), location string, and status. |
| 1 | cpqSiMemModuleEntry | A single memory module (DIMM) entry. Contains board number, slot index, size, speed, type, location, and condition status. |
| 1 | cpqSiMemModuleBoard | The board number on which this memory module is located. Used together with cpqSiMemModuleIndex to uniquely identify a DIMM slot. |
| 1 | cpqSiMemModuleIndex | The index of this memory module within the board. Counts from 1 for the first DIMM slot on the board. |
| 1 | cpqSiMemModuleSize | The size of this memory module in kilobytes. Divide by 1024 to get MB, by 1048576 to get GB. |
| 1 | cpqSiMemModuleType | The type of memory module: other(1), board(2), cpqSingleWidthModule(3), cpqDoubleWidthModule(4), simm(5), pcmcia(6), compaq-specific(7), DIMM(8), smallOutlineDimm(9), RIMM(10), SRIMM(11), FB-DIMM(12), DIMM-DDR(13), DIMM-DDR2(14), DIMM-DDR3(15), DIMM-DDR4(16). |
| 1 | cpqSiMemModuleLocation | A text string describing the physical location of this memory module (e.g. 'PROC 1 DIMM 1A'). |
| 1 | cpqSiMemModuleCondition | The condition of this memory module: other(1)=unknown, ok(2)=operating normally, degraded(3)=operating but with errors, failed(4)=has failed and should be replaced. |
| 1 | cpqSiMemModuleSpeed | The speed of this memory module in MHz (e.g. 2133, 2400, 2666 for DDR4). |
| 1 | cpqSiSysObjects | General server product information objects: product name, ROM version, and system configuration data. |
| 1 | cpqSiSysUtilLifeTime | The server's cumulative lifetime utilization counter in hours. Indicates total powered-on time since manufacturing. |
| 1 | cpqSiProductName | The marketing product name of this server as defined by HPE (e.g. 'ProLiant DL380 Gen9'). Used for display and identification purposes. |
| 1 | cpqSiRomVersion | The version identifier of the System ROM (BIOS/UEFI firmware) currently installed on this server. Format varies by generation (e.g. 'P89 02/17/2017'). |
| 1 | cpqSiSysEmbMgmt | Indicates whether the embedded systems management processor (iLO) is present: other(1), absent(2), present(3). |
| 1 | cpqSiSysEmbMgmtRevision | The revision level of the embedded systems management (iLO) subsystem firmware. |
| 1 | cpqSiAssetTag | Asset tag group. Contains the customer-defined asset tag string for this server, used for asset tracking and inventory management. |
| 1 | cpqSiAssetTagData | The asset tag string assigned to this server. This is a customer-configurable field used for asset tracking (up to 32 characters). |
| 1 | cpqSiAssetTagVersion | The version number of the asset tag data format. Used to determine how to interpret the asset tag string. |
| 1 | cpqSiAssetTagSize | The maximum size in bytes of the asset tag data field supported by this server's firmware. |
| 1 | cpqSiVpdInfo | Vital Product Data (VPD) group containing globally unique identifiers for this server. |
| 1 | cpqSiUUID | The Universal Unique Identifier (UUID) for this server. A 128-bit value assigned at manufacturing, formatted as 32 hex digits. Used by management software for unique system identification. |
| 1 | cpqSiWWID | The World Wide Identifier (WWID) for this server. Used in storage area network (SAN) environments to uniquely identify server HBAs. |
CPU
1.3.6.1.4.1.232.1.2.2
CPQSTDEQ: processor table (model, speed, stepping, core count, status per socket)
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqSeCpuTable | Processor table. Contains one entry per physical processor socket with model name, speed, stepping, core count, and status. |
| 1 | cpqSeCpuTableEntry | Processor table conceptual row container. |
| 1 | cpqSeCpuEntry | A single processor entry. Contains socket number, model name, speed, stepping, core count, and condition. |
| 1 | cpqSeCpuUnitIndex | The index of this processor entry, starting at 1. Each physical processor socket has a unique index. |
| 1 | cpqSeCpuSlot | The slot/socket number of this processor. Numbering starts at 0 for the first socket. |
| 1 | cpqSeCpuName | The name/model of this processor as reported by the hardware (e.g. 'Intel(R) Xeon(R) CPU E5-2690 v3 @ 2.60GHz'). |
| 1 | cpqSeCpuSpeed | The speed of this processor in MHz as reported by the hardware. |
| 1 | cpqSeCpuStep | The stepping of this processor. Identifies a specific revision of the processor die. |
| 1 | cpqSeCpuStatus | The status of this processor: unknown(1), ok(2), degraded(3), failed(4), disabled(5). A degraded status may indicate a cache failure or thermal throttling. |
| 1 | cpqSeCpuExtSpeed | The extended/turbo speed of this processor in MHz. May be higher than base speed if Intel Turbo Boost is active. |
| 1 | cpqSeCpuCore | The number of physical cores in this processor. |
| 1 | cpqSeCpuMaxSpeed | The maximum speed of this processor in MHz under optimal conditions. |
| 1 | cpqSeCpuFamily | The processor family name (e.g. 'Xeon'). |
| 1 | cpqSeCpuHyperthread | Indicates whether Intel Hyper-Threading is enabled: other(1), notSupported(2), disabled(3), enabled(4). |
Memory
1.3.6.1.4.1.232.6.2.14
CPQHLTH: memory module table (size, speed, type, location, error status)
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqHeResMemory | Memory health group. Contains tables for memory module status, error counts, and condition monitoring. |
| 1 | cpqHeResMemCondition | The overall health condition of the memory subsystem: other(1)=unknown, ok(2)=all modules ok, degraded(3)=one or more degraded, failed(4)=one or more failed. |
| 1 | cpqHeResMemOSMemSize | The total amount of memory (in MB) available to the operating system. |
| 1 | cpqHeResMemTotalMemSlots | The total number of memory module slots present in this server. |
| 1 | cpqHeResMemErrStatus | The status of any memory errors detected: other(1), noErrors(2), allMemoryNotMapped(3), uncorrectable(4). |
| 1 | cpqHeResMemHotPlug | Indicates whether this server supports online memory hot-plug: other(1), notSupported(2), supported(3). |
| 1 | cpqHeResMemSpeed | The operating speed of the installed memory in MHz (e.g. 2400). |
| 1 | cpqHeResMemInterleaveFactor | The memory interleave factor for the installed memory configuration. |
| 1 | cpqHeResMemTotalMemSize | The total amount of memory installed in this server in kilobytes. Divide by 1048576 to get GB. |
| 1 | cpqHeResMemSyncMode | The memory synchronization mode: other(1), independent(2), mirrored(3), lockstep(4). |
| 1 | cpqHeResMemBoardTable | Memory board table. Each entry describes one memory board/controller and its total installed memory. |
| 1 | cpqHeResMemBoardEntry | A single memory board entry. Contains board index, condition, installed module count, total size, and operating speed. |
| 1 | cpqHeResMemBoardIndex | The index of this memory board, starting at 0. |
| 1 | cpqHeResMemBoardCondition | The health condition of this memory board: other(1), ok(2), degraded(3), failed(4). |
| 1 | cpqHeResMemBoardModuleCount | The number of memory modules (DIMMs) installed on this board. |
| 1 | cpqHeResMemBoardTotalSize | The total installed memory on this board in kilobytes. Divide by 1048576 to get GB. |
| 1 | cpqHeResMemBoardSpeed | The operating speed of the memory on this board in MHz (e.g. 2400). |
| 1 | cpqHeResMemModuleTable | Memory module (DIMM) health table. Each entry represents one installed memory module with size, speed, type, location, and condition. |
| 1 | cpqHeResMemModuleEntry | A single memory module (DIMM) entry. Contains board number, slot index, size, speed, type, location, and health condition. |
| 1 | cpqHeResMemBoardNum | The board number on which this memory module is located. |
| 1 | cpqHeResMemModuleNum | The slot number of this memory module on the board. |
| 1 | cpqHeResMemModuleCondition | The overall health condition of this memory module: other(1), notPresent(2), ok(3), degraded(4), degradedModuleIndexUnknown(5), failed(6), failedDimmEcc(7). |
| 1 | cpqHeResMemModuleSize | The size of this memory module in kilobytes. Divide by 1048576 to get GB. |
| 1 | cpqHeResMemModuleType | The type of this memory module: DIMM(8), RIMM(10), FB-DIMM(12), DDR3(15), DDR4(16), DDR5(17). |
| 1 | cpqHeResMemModuleSpeed | The operating speed of this memory module in MHz (e.g. 2133, 2400, 2666 for DDR4). |
Storage
1.3.6.1.4.1.232.3
CPQDA: array controller, logical/physical drive table, RAID level, capacity, fault tolerance
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqDaMIB | HPE CPQDA-MIB root. Drive Array MIB covering Smart Array controllers, logical drives, physical drives, and spare drives. |
| 1 | cpqDaComponent | Drive Array objects group. Contains all CPQDA tables: controllers, logical drives, physical drives, and spare drives. |
| 1 | cpqDaCntlr | The controller table. This table is for management and configuration of Drive Array controllers. |
| 1 | cpqDaCntlrTableEntry | Array controller table conceptual row container. |
| 1 | cpqDaCntlrEntry | A single disk array controller entry containing slot number, model, firmware revision, redundancy status, and fault tolerance. |
| 1 | cpqDaCntlrIndex | The index of this array controller, starting at 1. |
| 1 | cpqDaCntlrModel | The model of this array controller (e.g. 'Smart Array P440ar', 'Smart Array E208i-a SR Gen10'). |
| 1 | cpqDaCntlrState | The current state of this controller: other(1), ok(2), generalFailure(3), cableProblem(4), poweredOff(5). |
| 1 | cpqDaCntlrCondition | The condition of this array controller: other(1), ok(2), degraded(3), failed(4). A failed controller requires immediate replacement. |
| 1 | cpqDaCntlrFWVersion | The firmware version of this array controller as a string (e.g. '6.64-0'). |
| 1 | cpqDaCntlrSerialNumber | The serial number of this array controller. |
| 1 | cpqDaCntlrSlot | The PCI slot number where this array controller is installed. Slot 0 typically indicates an embedded controller. |
| 1 | cpqDaLogDrv | The logical drive configuration table. Logical drives are created from physical drives using a controller. |
| 1 | cpqDaLogDrvTableEntry | Logical drive table conceptual row container. |
| 1 | cpqDaLogDrvEntry | A single logical drive entry. Contains RAID level, capacity in MB, status, fault tolerance, and accelerator information. |
| 1 | cpqDaLogDrvIndex | The logical drive number on this controller, starting at 1. |
| 1 | cpqDaLogDrvFaultTol | The fault tolerance method for this logical drive: other(1), none/RAID0(2), mirroring/RAID1(3), dataGuard/RAID5(4), distribDataGuard/RAID5(5), enhancedDataGuard/RAID6(6). Corresponds to RAID 0/1/5/6/ADM. |
| 1 | cpqDaLogDrvStatus | The current status of this logical drive: other(1), ok(2), failed(3), unconfigured(4), recovering(5), readyForRebuild(6), rebuilding(7), wrongDrive(8), badConnect(9), overheating(10), shutdown(11), expanding(12), notAvailable(13), queuedForExpansion(14). |
| 1 | cpqDaLogDrvSize | The size of this logical drive in megabytes. |
| 1 | cpqDaSpareDrv | The spare drive table for management of hot spare drives. |
| 1 | cpqDaPhyDrv | The physical drive table containing status and attribute information for all physical drives. |
| 1 | cpqDaPhyDrvTableEntry | Physical drive table conceptual row container. |
| 1 | cpqDaPhyDrvEntry | A single physical drive entry. Contains bay number, model, size, status, temperature, and failure prediction data. |
| 1 | cpqDaPhyDrvBay | The drive bay number where this physical drive is installed. |
| 1 | cpqDaPhyDrvModel | The model identifier string of this physical drive as reported by the firmware. |
| 1 | cpqDaPhyDrvStatus | The status of this physical drive: other(1), ok(2), failed(3), predictiveFailure(4), erasing(5), eraseDone(6), eraseQueued(7), ssdWearOut(8). Predictive failure indicates the drive is likely to fail soon. |
| 1 | cpqDaPhyDrvTemperatureCelsius | Current temperature of this physical drive in degrees Celsius. High temperatures can shorten drive lifespan. |
| 1 | cpqDaPhyDrvTemperatureThreshold | Temperature warning threshold for this drive in Celsius. Temperatures above this value may trigger proactive replacement. |
Fans
1.3.6.1.4.1.232.6.2.6
CPQHLTH: fan table (location, speed, redundancy state, condition: OK/Degraded/Failed)
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqHeThermal | Thermal and fan management group. Contains overall thermal condition, temperature sensor table, fault-tolerant fan table, and thermal action scalars. |
| 1 | cpqHeThermalCondition | The overall condition of the system's thermal environment. This is the combined condition of all temperature sensors and cooling devices. |
| 1 | cpqHeThermalDegradedAction | The action to take if the system's thermal condition becomes degraded. |
| 1 | cpqHeThermalTempStatus | The status of the system's temperature sensors. |
| 1 | cpqHeThermalSystemFanStatus | The status of the fan(s) in the system. |
| 1 | cpqHeThermalCpuFanStatus | The status of the processor fan(s) in the system. |
| 1 | cpqHeThermalFanTable | A table of fan descriptions maintained by the health management subsystem. |
| 1 | cpqHeFltTolFanTable | A table of Fault Tolerant Fan Entries. The fault tolerant fan subsystem is designed to provide an additional level of cooling reliability. |
| 1 | cpqHeFltTolFanEntry | A single fan entry from the fault-tolerant fan table. Contains fan index, locale, present status, speed, and redundancy condition. |
| 1 | cpqHeFltTolFanChassis | The chassis number of the server containing this fan. |
| 1 | cpqHeFltTolFanIndex | The index of this fan unit within the chassis, starting at 1. |
| 1 | cpqHeFltTolFanLocale | The physical location of this fan as an enumerated value: other(1), unknown(2), system(3), systemBoard(4), ioBoard(5), cpu(6), memory(7), storage(8), removableMedia(9), powerSupply(10), ambient(11), chassis(12), bridgeCard(13). |
| 1 | cpqHeFltTolFanPresent | Indicates whether this fan is physically present: other(1), absent(2), present(3). |
| 1 | cpqHeFltTolFanSpeed | The current speed of this fan as a percentage of maximum speed: other(1), normal(2), high(3). |
| 1 | cpqHeFltTolFanCondition | The condition of this fan: other(1)=unknown, ok(2)=operating normally, degraded(3)=operating at reduced performance, failed(4)=failed and requires replacement. |
| 1 | cpqHeFltTolFanHotPlug | Indicates whether this fan supports hot-plug replacement without powering down the server: other(1), nonHotPlug(2), hotPlug(3). |
Temps
1.3.6.1.4.1.232.6.2.6.8
CPQHLTH: temperature sensor table (location, current reading, warning/critical thresholds)
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqHeTemperatureTable | A table of Temperature Sensor Entries maintained by the health management subsystem. |
| 1 | cpqHeTemperatureEntry | A single temperature sensor entry. Contains the sensor location description, current reading in Celsius, warning and critical thresholds, and overall condition. |
| 1 | cpqHeThermalIndex | The index of this temperature sensor, used together with cpqHeThermalChassis to uniquely identify a sensor. |
| 1 | cpqHeThermalChassis | The chassis number of the server subsystem containing this temperature sensor. |
| 1 | cpqHeThermalTempCelsius | The current temperature reading of this sensor in degrees Celsius. |
| 1 | cpqHeThermalTempThreshold | The warning threshold for this temperature sensor in degrees Celsius. If the temperature exceeds this value, a warning event is generated. |
| 1 | cpqHeThermalCondition | The condition of this temperature sensor: other(1)=unknown, ok(2)=within normal range, degraded(3)=warning threshold exceeded, failed(4)=critical threshold exceeded. |
| 1 | cpqHeThermalLocale | The physical location of this temperature sensor as an enumerated value. Indicates whether it monitors CPU, memory, I/O bay, power supply, system board, etc. |
| 1 | cpqHeThermalTempCritical | The critical/shutdown threshold for this temperature sensor in degrees Celsius. If exceeded, the server may automatically shut down to prevent hardware damage. |
Power/PSU
1.3.6.1.4.1.232.6.2.9
CPQHLTH: power supply table (present, redundancy, input line status, capacity in watts)
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqHeFltTolPwrSupply | Fault-tolerant power supply group. Contains overall PSU condition, redundancy status, and the power supply table with per-PSU health and capacity. |
| 1 | cpqHeFltTolPwrSupplyCondition | The overall condition of the fault tolerant power supply sub-system. |
| 1 | cpqHeFltTolPwrSupplyStatus | The status of the fault tolerant power supply. This is the combined status of all power supply slots. |
| 1 | cpqHeFltTolPowerSupplyTable | A table of Power Supply Entries maintained by the health management subsystem. |
| 1 | cpqHeFltTolPowerSupplyEntry | A single power supply entry. Contains chassis/bay index, presence status, condition, input line status, power output in watts, and serial number. |
| 1 | cpqHeFltTolPowerSupplyChassis | The chassis number of the server containing this power supply. |
| 1 | cpqHeFltTolPowerSupplyBay | The bay number of this power supply within the chassis, starting at 1. |
| 1 | cpqHeFltTolPowerSupplyPresent | Whether this power supply bay is physically occupied: other(1), absent(2), present(3). |
| 1 | cpqHeFltTolPowerSupplyCondition | The operational condition of this power supply: other(1), ok(2), degraded(3), failed(4). A failed PSU requires immediate replacement. |
| 1 | cpqHeFltTolPowerSupplyInputLineStatus | The status of the AC input line to this power supply: other(1), noError(2), lineOverVoltage(3), lineUnderVoltage(4), lineHit(5), brownout(6), linePowerLoss(7). |
| 1 | cpqHeFltTolPowerSupplyCapacityUsed | The current power output of this power supply in watts. |
| 1 | cpqHeFltTolPowerSupplyCapacityMaximum | The maximum rated power output capacity of this power supply in watts (e.g. 460, 750, 1400). |
| 1 | cpqHeFltTolPowerSupplyRedundant | Whether this PSU is in a redundant configuration: other(1), notRedundant(2), redundant(3). Redundant means at least one additional PSU could handle the load if this one fails. |
| 1 | cpqHeFltTolPowerSupplyModel | The model/part number string of this power supply as reported by the firmware. |
| 1 | cpqHeFltTolPowerSupplySerialNumber | The serial number of this power supply, used for spare part ordering and support. |
NIC
1.3.6.1.4.1.232.18
CPQNIC: NIC table (description, team name, MAC address, driver version, statistics)
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqNicMIB | HPE CPQNIC-MIB root. Network Interface Controller MIB covering NIC teaming, link status, speed, duplex, driver version, and statistics. |
| 1 | cpqNicIf | The NIC interface group. Contains information for all network interface controllers managed by the CPQNIC-MIB, including link status, speed, duplex, and driver information. |
Health
1.3.6.1.4.1.232.6
CPQHLTH: overall health status, thermal status, memory status, event log
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqHealthMIB | HPE CPQHLTH-MIB root. Contains all Health Management MIB objects: thermal sensors, fans, power supplies, memory health, ASR, and system health status. |
| 1 | cpqHeComponent | HPE CPQHLTH-MIB revision group. Contains major/minor/dev version of the HPE Health Management (Insight Management Agents) software. |
| 1 | cpqHeSysHwRevMajor | Major revision of the HPE Health Management software installed on this server. |
| 1 | cpqHeSysHwRevMinor | Minor revision of the HPE Health Management software installed on this server. |
| 1 | cpqHeSysHwRevDev | Development/build revision of the HPE Health Management software installed on this server. |
| 1 | cpqHeMComponent | HPE health management objects group. Contains thermal, fan, power supply, memory, and system health sub-groups. |
| 1 | cpqHeSysHealth | System health status group. Contains overall system health condition, POST status, and fault information. |
| 1 | cpqHeSysHealthStatus | The overall health status of the server: other(1), ok(2), degraded(3), failed(4). A degraded status means a non-critical component requires attention. |
| 1 | cpqHeSysPostStatus | The result of the server's last Power-On Self Test (POST): other(1), ok(2). A non-ok value may indicate a hardware problem detected at boot. |
| 1 | cpqHeSysDriveArrayStatus | The combined status of all drive arrays in this server: other(1), ok(2), degraded(3), failed(4). |
| 1 | cpqHeSysAsrStatus | The automatic server recovery (ASR) status: other(1), notProtected(2), protected(3). Protected means ASR will restart the server on OS hang. |
| 1 | cpqHeSysNicStatus | The combined NIC health status: other(1), ok(2), degraded(3), failed(4). |
iLO
1.3.6.1.4.1.232.9
iLO MIB: iLO IP/hostname, firmware version, license type, active sessions, power state
| OID | Name | Beschreibung |
|---|---|---|
| 1 | cpqSm2MIB | HPE CPQSM2-MIB root. iLO (Integrated Lights-Out) MIB covering remote management processor status, firmware version, license, active sessions, and the event log. |
| 1 | cpqSm2Fix | The iLO (Integrated Lights-Out) management group. Contains scalar controller objects and the event log table for the HPE iLO management processor. |
| 1 | cpqSm2CntlrObjects | HPE iLO (CPQSM2-MIB) management controller scalar objects. Contains iLO firmware version, IP address, HTTP/HTTPS ports, MAC address, license key, and operational status fields. |
| 1 | cpqSm2CntlrHwRevision | The hardware revision of the iLO management processor board. |
| 1 | cpqSm2CntlrFWRevision | The firmware version string of the iLO management processor (e.g. '2.54 Jul 02 2019'). |
| 1 | cpqSm2CntlrIpAddress | The IPv4 address assigned to the iLO dedicated management network port. |
| 1 | cpqSm2CntlrHttpPort | TCP port for iLO HTTP management access (default 80). |
| 1 | cpqSm2CntlrHttpsPort | TCP port for iLO HTTPS secure management access (default 443). |
| 1 | cpqSm2CntlrLicenseType | The type of iLO license installed: other(1), unlicensed(2), iloAdvanced(3). Advanced license enables remote console, power management, and other features. |
| 1 | cpqSm2CntlrAlertStatus | The iLO alert status: other(1), noAlerts(2), pendingAlerts(3). Indicates whether there are unsent remote support alerts. |
| 1 | cpqSm2CntlrRemoteSessionCount | The number of active remote console sessions on this iLO management processor. |
| 1 | cpqSm2CntlrMacAddress | The MAC address of the iLO dedicated management network port. |
| 1 | cpqSm2CntlrEnabled | Whether the iLO management processor is currently enabled: other(1), disabled(2), enabled(3). |
| 1 | cpqSm2CntlrIpV6Address | The IPv6 address assigned to the iLO management port (0.0.0.0 if not configured). |
| 1 | cpqSm2CntlrServerSerial | The server serial number as reported by the iLO management processor. |
| 1 | cpqSm2CntlrLicenseKey | The iLO Advanced license key string installed on this server. iLO Advanced enables remote console, power management, and advanced monitoring. |
| 1 | cpqSm2EventLog | HPE iLO Integrated Management Log (IML) table. Contains server health and fault events logged by the iLO management processor including hardware failures, POST errors, and temperature alerts. |
Probieren Sie es in SNMP Explorer für Mac