Other Vendors: OID-Referenz

147 OIDs der Gruppe Other Vendors mit Name und MIB-Beschreibung, wie sie SNMP Explorer für Mac von Haus aus kennt.

Dell

1.3.6.1.4.1.674

Dell OpenManage MIBs: server hardware health, storage, iDRAC

OIDNameBeschreibung
1.3.6.1.4.1.674.10892.5.4 systemDetailsGroup The system details group containing monitoring objects for Dell iDRAC managed servers.
1.3.6.1.4.1.674.10892.5.4.600.10 powerUnitTable This object defines the Power Unit Table. The table contains information about the power units contained by the chassis.
1.3.6.1.4.1.674.10892.5.4.600.12 powerSupplyTable This object defines the Power Supply Table. The table contains information about the power supplies contained by the chassis.
1.3.6.1.4.1.674.10892.5.4.600.20 voltageProbeTable This object defines the Voltage Probe Table. The table contains information about the voltage probes contained by the chassis.
1.3.6.1.4.1.674.10892.5.4.600.30 amperageProbeTable This object defines the Amperage Probe Table. The table contains information about the amperage probes contained by the chassis.
1.3.6.1.4.1.674.10892.5.4.600.50 systemBatteryTable This object defines the System Battery Table. The table contains information about the batteries contained by the chassis.
1.3.6.1.4.1.674.10892.5.4.600.60 powerUsageTable This object defines the Power Usage Table. The table contains information about the power usage of the chassis.
1.3.6.1.4.1.674.10892.5.4.700.10 coolingUnitTable This object defines the Cooling Unit Table. The table contains information about the cooling units contained by the chassis.
1.3.6.1.4.1.674.10892.5.4.700.12 coolingDeviceTable This object defines the Cooling Device Table. The table contains information about the cooling devices (fans) contained by the chassis.
1.3.6.1.4.1.674.10892.5.4.700.20 temperatureProbeTable This object defines the Temperature Probe Table. The table contains information about the temperature probes contained by the chassis.

Nach oben ↑

APC / UPS

1.3.6.1.4.1.318

APC UPS MIB: battery charge/runtime/status, input/output voltage, load percent, alarms

OIDNameBeschreibung
1.3.6.1.4.1.318.1.1.1.2.2.1 upsAdvBatteryCapacity The remaining battery capacity expressed in percent of full capacity.
1.3.6.1.4.1.318.1.1.1.2.2.2 upsAdvBatteryTemperature The current internal UPS temperature expressed in Celsius.
1.3.6.1.4.1.318.1.1.1.2.2.3 upsAdvBatteryRunTimeRemaining The UPS battery run time remaining before battery exhaustion, expressed in hundredths of a second.
1.3.6.1.4.1.318.1.1.1.2.2.4 upsAdvBatteryReplaceIndicator Indicates whether the UPS batteries need replacing. noBatteryNeedsReplacing(1) or batteryNeedsReplacing(2).
1.3.6.1.4.1.318.1.1.1.2.2.5 upsAdvBatteryNumOfBattPacks The number of external battery packs connected to the UPS. If the number of external battery packs is unknown, -1 is returned.
1.3.6.1.4.1.318.1.1.1.2.2.6 upsAdvBatteryNumOfBadBattPacks The number of external battery packs connected to the UPS that are defective. If the number of defective external battery packs is unknown, -1 is returned.
1.3.6.1.4.1.318.1.1.1.2.2.7 upsAdvBatteryNominalVoltage The nominal battery voltage in Volts.
1.3.6.1.4.1.318.1.1.1.2.2.8 upsAdvBatteryActualVoltage The actual battery bus voltage in Volts.
1.3.6.1.4.1.318.1.1.1.2.2.9 upsAdvBatteryCurrent The battery current in Amps.
1.3.6.1.4.1.318.1.1.1.2.2.10 upsAdvTotalDCCurrent The total DC current in Amps.
1.3.6.1.4.1.318.1.1.1.2.2.11 upsAdvBatteryFullCapacity The full chargeable capacity of the battery expressed in percentage.
1.3.6.1.4.1.318.1.1.1.2.2.21 upsAdvBatteryRecommendedReplaceDate The recommended battery replacement date based on APC's battery life algorithm.
1.3.6.1.4.1.318.1.1.1.3.2.1 upsAdvInputLineVoltage The current utility line voltage in VAC.
1.3.6.1.4.1.318.1.1.1.3.2.2 upsAdvInputMaxLineVoltage The maximum utility line voltage in VAC over the previous 1 minute period.
1.3.6.1.4.1.318.1.1.1.3.2.3 upsAdvInputMinLineVoltage The minimum utility line voltage in VAC over the previous 1 minute period.
1.3.6.1.4.1.318.1.1.1.3.2.4 upsAdvInputFrequency The current input frequency to the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.3.2.5 upsAdvInputLineFailCause The reason for the occurrence of the last transfer to UPS battery power. The variable is set to: noTransfer(1) if there has been no transfer. highLineVoltage(2) if the transfer to battery is caused by an over voltage situation. brownout(3) if the duration of the brownout is greater than 5 seconds. blackout(4) if there was a complete loss of input power. smallMomentarySag(5) if the duration of the momentary sag is greater than 1 second. deepMomentarySag(6) if the duration of the sag is greater than 1 second.
1.3.6.1.4.1.318.1.1.1.3.2.6 upsAdvInputNominalFrequency The nominal input frequency of the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.3.2.7 upsAdvInputNominalVoltage The nominal input voltage of the UPS system in VAC.
1.3.6.1.4.1.318.1.1.1.4.2.1 upsAdvOutputVoltage The output voltage of the UPS system in VAC.
1.3.6.1.4.1.318.1.1.1.4.2.2 upsAdvOutputFrequency The current output frequency of the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.4.2.3 upsAdvOutputLoad The current UPS load expressed as a percentage of the rated capacity.
1.3.6.1.4.1.318.1.1.1.4.2.4 upsAdvOutputCurrent The current in Amperes drawn by the load on the UPS.
1.3.6.1.4.1.318.1.1.1.4.2.5 upsAdvOutputRedundancy The number of power modules that can fail or be removed without causing the UPS to generate a Minimum Redundancy Lost event.
1.3.6.1.4.1.318.1.1.1.4.2.6 upsAdvOutputKVACapacity The maximum load that this UPS can support.
1.3.6.1.4.1.318.1.1.1.4.2.7 upsAdvOutputNominalFrequency The nominal output frequency of the UPS system in Hz.
1.3.6.1.4.1.318.1.1.1.4.2.8 upsAdvOutputActivePower The total output active power of the UPS system in W.
1.3.6.1.4.1.318.1.1.1.4.2.9 upsAdvOutputApparentPower The total output apparent power of all phases of the UPS system in VA.

Nach oben ↑

F5

1.3.6.1.4.1.3375

F5 BIG-IP MIBs: virtual server stats, pool member health, throughput, connections

OIDNameBeschreibung
1.3.6.1.4.1.3375.2.2.4.1 ltmNodeAddr The node address configuration table. Each row represents a node server with its address and configuration.
1.3.6.1.4.1.3375.2.2.4.2 ltmNodeAddrStat The node address statistics table. Contains traffic and connection statistics for each node.
1.3.6.1.4.1.3375.2.2.4.3 ltmNodeAddrStatus The node address status table. Contains current health and availability status for each node.
1.3.6.1.4.1.3375.2.2.5.1 ltmPool The pool configuration table. Each row represents a pool with its load-balancing algorithm, status, and configuration.
1.3.6.1.4.1.3375.2.2.5.2 ltmPoolStat The pool statistics table. Contains aggregate traffic and connection statistics for each pool.
1.3.6.1.4.1.3375.2.2.5.3 ltmPoolMember The pool member configuration table. Each row represents a member (node:port) of a pool.
1.3.6.1.4.1.3375.2.2.5.4 ltmPoolMemberStat The pool member statistics table. Contains per-member traffic and connection statistics.
1.3.6.1.4.1.3375.2.2.5.5 ltmPoolStatus The pool status table. Contains current health and availability status for each pool.
1.3.6.1.4.1.3375.2.2.5.6 ltmPoolMemberStatus The pool member status table. Contains current health and availability status for each pool member.
1.3.6.1.4.1.3375.2.2.10.1 ltmVirtualServ The virtual server configuration table. Each row represents a virtual server with its address, port, and configuration.
1.3.6.1.4.1.3375.2.2.10.2 ltmVirtualServStat The virtual server statistics table. Contains traffic, connection, and performance statistics for each virtual server.
1.3.6.1.4.1.3375.2.2.10.10 ltmVirtualAddr The virtual address configuration table. Each row represents a virtual address that may be shared across virtual servers.
1.3.6.1.4.1.3375.2.2.10.11 ltmVirtualAddrStat The virtual address statistics table. Contains traffic statistics aggregated at the virtual address level.
1.3.6.1.4.1.3375.2.2.10.13 ltmVirtualServStatus The virtual server status table. Contains current health and availability status for each virtual server.
1.3.6.1.4.1.3375.2.2.10.14 ltmVirtualAddrStatus The virtual address status table. Contains current health and availability status for each virtual address.

Nach oben ↑

Palo Alto

1.3.6.1.4.1.25461

Palo Alto Networks MIBs: session table, HA state, threat prevention stats, GlobalProtect

OIDNameBeschreibung
1.3.6.1.4.1.25461.2.1.2.1.1 panSysSwVersion Full software version. The first two components of the full version are the major and minor versions.
1.3.6.1.4.1.25461.2.1.2.1.2 panSysHwVersion Hardware version of the Palo Alto Networks device.
1.3.6.1.4.1.25461.2.1.2.1.3 panSysSerialNumber The serial number of the unit. If not available, an empty string is returned.
1.3.6.1.4.1.25461.2.1.2.1.4 panSysTimeZoneOffset The offset in seconds from UTC of the system's time zone. This value is negative for time zones west of UTC.
1.3.6.1.4.1.25461.2.1.2.1.5 panSysDaylightSaving Indicates whether daylight savings time is currently in effect.
1.3.6.1.4.1.25461.2.1.2.1.6 panSysVpnClientVersion Currently installed VPN client package version. If package is not installed, 0.0.0 is returned.
1.3.6.1.4.1.25461.2.1.2.1.7 panSysAppVersion Application definition version currently installed on the device.
1.3.6.1.4.1.25461.2.1.2.1.8 panSysAvVersion Antivirus version currently installed on the device.
1.3.6.1.4.1.25461.2.1.2.1.9 panSysThreatVersion Threat definition version currently installed on the device.
1.3.6.1.4.1.25461.2.1.2.1.10 panSysUrlFilteringVersion URL filtering database version currently installed on the device.
1.3.6.1.4.1.25461.2.1.2.1.11 panSysHAState Current high-availability state of this device (e.g., active, passive, initial).
1.3.6.1.4.1.25461.2.1.2.1.12 panSysHAPeerState Current high-availability state of the HA peer device.
1.3.6.1.4.1.25461.2.1.2.1.13 panSysHAMode Current high-availability mode: disabled, active-passive, or active-active.
1.3.6.1.4.1.25461.2.1.2.1.14 panSysUrlFilteringDatabase Current installed URL filtering database type (e.g., surfcontrol, brightcloud).
1.3.6.1.4.1.25461.2.1.2.1.15 panSysGlobalProtectClientVersion GlobalProtect client package version currently installed.
1.3.6.1.4.1.25461.2.1.2.1.16 panSysOpswatDatafileVersion Installed OPSWAT database version for host information profile matching.
1.3.6.1.4.1.25461.2.1.2.3.1 panSessionUtilization Session table utilization percentage. Values should be between 0 and 100.
1.3.6.1.4.1.25461.2.1.2.3.2 panSessionMax Total maximum sessions supported by the device.
1.3.6.1.4.1.25461.2.1.2.3.3 panSessionActive Total number of active sessions currently on the device.
1.3.6.1.4.1.25461.2.1.2.3.4 panSessionActiveTcp Total number of active TCP sessions.
1.3.6.1.4.1.25461.2.1.2.3.5 panSessionActiveUdp Total number of active UDP sessions.
1.3.6.1.4.1.25461.2.1.2.3.6 panSessionActiveICMP Total number of active ICMP sessions.
1.3.6.1.4.1.25461.2.1.2.3.7 panSessionActiveSslProxy Total number of active SSL proxy sessions.
1.3.6.1.4.1.25461.2.1.2.3.8 panSessionSslProxyUtilization SSL proxy session utilization percentage. Values should be between 0 and 100.

Nach oben ↑

Fortinet

1.3.6.1.4.1.12356

Fortinet FortiGate MIBs: CPU/memory, VPN tunnels, HA state, UTM statistics

OIDNameBeschreibung
1.3.6.1.4.1.12356.101.4.1.1 fgSysVersion Firmware version of the device.
1.3.6.1.4.1.12356.101.4.1.2 fgSysMgmtVdom Index that identifies the management virtual domain.
1.3.6.1.4.1.12356.101.4.1.3 fgSysCpuUsage Current CPU usage (percentage).
1.3.6.1.4.1.12356.101.4.1.4 fgSysMemUsage Current memory utilization (percentage).
1.3.6.1.4.1.12356.101.4.1.5 fgSysMemCapacity Total physical memory (RAM) installed (KB).
1.3.6.1.4.1.12356.101.4.1.6 fgSysDiskUsage Current hard disk usage (MB).
1.3.6.1.4.1.12356.101.4.1.7 fgSysDiskCapacity Total hard disk capacity (MB).
1.3.6.1.4.1.12356.101.4.1.8 fgSysSesCount Number of active sessions on the device.
1.3.6.1.4.1.12356.101.4.1.9 fgSysLowMemUsage Current kernel (low) memory utilization (percentage).
1.3.6.1.4.1.12356.101.4.1.10 fgSysLowMemCapacity Total kernel (low) memory capacity (KB).
1.3.6.1.4.1.12356.101.4.1.11 fgSysSesRate1 Average session setup rate over the past 1 minute, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.12 fgSysSesRate10 Average session setup rate over the past 10 minutes, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.13 fgSysSesRate30 Average session setup rate over the past 30 minutes, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.14 fgSysSesRate60 Average session setup rate over the past 60 minutes, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.15 fgSysSes6Count Number of active IPv6 sessions on the device.
1.3.6.1.4.1.12356.101.4.1.16 fgSysSes6Rate1 Average IPv6 session setup rate over the past 1 minute, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.17 fgSysSes6Rate10 Average IPv6 session setup rate over the past 10 minutes, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.18 fgSysSes6Rate30 Average IPv6 session setup rate over the past 30 minutes, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.19 fgSysSes6Rate60 Average IPv6 session setup rate over the past 60 minutes, in sessions per second.
1.3.6.1.4.1.12356.101.4.1.20 fgSysUpTime The 64-bit time (in hundredths of a second) since the network management portion of the system was last re-initialized.
1.3.6.1.4.1.12356.101.4.6.1.1 fgSIAdvMemPageCache The amount of physical RAM used as cache memory for files read from the disk (kB).
1.3.6.1.4.1.12356.101.4.6.1.2 fgSIAdvMemCacheActive The total amount of buffer or page cache memory that are active, in kilobytes.
1.3.6.1.4.1.12356.101.4.6.1.3 fgSIAdvMemCacheInactive The total amount of buffer or page cache memory that are free and available, in kilobytes.
1.3.6.1.4.1.12356.101.4.6.1.4 fgSIAdvMemBuffer The amount of physical RAM used for filesystem buffers (kB).
1.3.6.1.4.1.12356.101.4.6.1.5 fgSIAdvMemEnterKerConsThrsh The threshold at which the system will enter kernel memory conserve mode (percentage).
1.3.6.1.4.1.12356.101.4.6.1.6 fgSIAdvMemLeaveKerConsThrsh The threshold at which the system will exit kernel memory conserve mode (percentage).
1.3.6.1.4.1.12356.101.4.6.1.7 fgSIAdvMemEnterProxyConsThrsh The threshold at which the system will enter proxy memory conserve mode (percentage).
1.3.6.1.4.1.12356.101.4.6.1.8 fgSIAdvMemLeaveProxyConsThrsh The threshold at which the system will exit proxy memory conserve mode (percentage).
1.3.6.1.4.1.12356.101.4.6.2.1 fgSIAdvSesEphemeralCount The current number of ephemeral sessions on the device.
1.3.6.1.4.1.12356.101.4.6.2.2 fgSIAdvSesEphemeralLimit The limit number of allowed ephemeral sessions on the device.
1.3.6.1.4.1.12356.101.4.6.2.3 fgSIAdvSesClashCount The number of new sessions which have collision with existing sessions.
1.3.6.1.4.1.12356.101.4.6.2.4 fgSIAdvSesExpCount The number of current expectation sessions.
1.3.6.1.4.1.12356.101.4.6.2.5 fgSIAdvSesSyncQFCount The sync queue full counter, reflecting bursts on the sync queue.
1.3.6.1.4.1.12356.101.4.6.2.6 fgSIAdvSesAcceptQFCount The accept queue full counter, reflecting bursts on the accept queue.
1.3.6.1.4.1.12356.101.4.6.2.7 fgSIAdvSesNoListenerCount The number of direct requests to FortiGate local stack from external sources, which may indicate potential DoS activity.
1.3.6.1.4.1.12356.101.12.2.2.1.1 fgVpnTunEntIndex An index value that uniquely identifies a VPN tunnel within the fgVpnTunTable.
1.3.6.1.4.1.12356.101.12.2.2.1.2 fgVpnTunEntPhase1Name The name of the phase 1 configuration associated with the tunnel.
1.3.6.1.4.1.12356.101.12.2.2.1.3 fgVpnTunEntPhase2Name The name of the phase 2 configuration associated with the tunnel.
1.3.6.1.4.1.12356.101.12.2.2.1.4 fgVpnTunEntRemGwyIp IP address of the remote gateway used by this tunnel.
1.3.6.1.4.1.12356.101.12.2.2.1.5 fgVpnTunEntRemGwyPort Port of the remote gateway for UDP-encapsulated tunnels.
1.3.6.1.4.1.12356.101.12.2.2.1.6 fgVpnTunEntLocGwyIp IP address of the local gateway used by this tunnel.
1.3.6.1.4.1.12356.101.12.2.2.1.7 fgVpnTunEntLocGwyPort Port of the local gateway for UDP-encapsulated tunnels.
1.3.6.1.4.1.12356.101.12.2.2.1.8 fgVpnTunEntSelectorSrcBeginIp Beginning of the source IP address range in the security association selector.
1.3.6.1.4.1.12356.101.12.2.2.1.9 fgVpnTunEntSelectorSrcEndIp End of the source IP address range in the security association selector.
1.3.6.1.4.1.12356.101.12.2.2.1.10 fgVpnTunEntSelectorSrcPort Source port for the security association selector.
1.3.6.1.4.1.12356.101.12.2.2.1.11 fgVpnTunEntSelectorDstBeginIp Beginning of the destination IP address range in the security association selector.
1.3.6.1.4.1.12356.101.12.2.2.1.12 fgVpnTunEntSelectorDstEndIp End of the destination IP address range in the security association selector.
1.3.6.1.4.1.12356.101.12.2.2.1.13 fgVpnTunEntSelectorDstPort Destination port for the security association selector.
1.3.6.1.4.1.12356.101.12.2.2.1.14 fgVpnTunEntSelectorProto Protocol number for the security association selector.
1.3.6.1.4.1.12356.101.12.2.2.1.15 fgVpnTunEntLifeSecs Lifetime of this tunnel in seconds (time-based lifetime).
1.3.6.1.4.1.12356.101.12.2.2.1.16 fgVpnTunEntLifeBytes Lifetime of tunnel in bytes transferred (byte-transfer-based lifetime).
1.3.6.1.4.1.12356.101.12.2.2.1.17 fgVpnTunEntTimeout Idle timeout of the tunnel in seconds.
1.3.6.1.4.1.12356.101.12.2.2.1.18 fgVpnTunEntInOctets Number of bytes received on this tunnel.
1.3.6.1.4.1.12356.101.12.2.2.1.19 fgVpnTunEntOutOctets Number of bytes sent out on this tunnel.
1.3.6.1.4.1.12356.101.12.2.2.1.20 fgVpnTunEntStatus Current status of tunnel: 1=down, 2=up.
1.3.6.1.4.1.12356.101.12.2.2.1.21 fgVpnTunEntVdom The virtual domain the tunnel belongs to.
1.3.6.1.4.1.12356.101.12.2.3.1.1 fgVpnSslState Whether SSL-VPN is enabled on this virtual domain.
1.3.6.1.4.1.12356.101.12.2.3.1.2 fgVpnSslStatsLoginUsers The current number of users logged in through SSL-VPN tunnels in the virtual domain.
1.3.6.1.4.1.12356.101.12.2.3.1.3 fgVpnSslStatsMaxUsers The maximum number of total users that can be logged in at any one time on the virtual domain.
1.3.6.1.4.1.12356.101.12.2.3.1.4 fgVpnSslStatsActiveWebSessions The current number of active SSL web sessions in the virtual domain.
1.3.6.1.4.1.12356.101.12.2.3.1.5 fgVpnSslStatsMaxWebSessions The maximum number of active SSL web sessions allowed at any one time within the virtual domain.
1.3.6.1.4.1.12356.101.12.2.3.1.6 fgVpnSslStatsActiveTunnels The current number of active SSL tunnels in the virtual domain.
1.3.6.1.4.1.12356.101.12.2.3.1.7 fgVpnSslStatsMaxTunnels The maximum number of active SSL tunnels allowed at any one time in the virtual domain.
1.3.6.1.4.1.12356.101.13.1.1 fgHaSystemMode High-availability mode: Standalone, Active-Active, or Active-Passive.
1.3.6.1.4.1.12356.101.13.1.2 fgHaGroupId HA cluster group ID the device is configured for.
1.3.6.1.4.1.12356.101.13.1.3 fgHaPriority HA clustering priority of the device (default = 127). Higher values give higher priority for master election.
1.3.6.1.4.1.12356.101.13.1.4 fgHaOverride Status of the master override flag. When enabled, this device will become master regardless of monitored interface status.
1.3.6.1.4.1.12356.101.13.1.5 fgHaAutoSync Configuration of automatic configuration synchronization between cluster members (enabled or disabled).
1.3.6.1.4.1.12356.101.13.1.6 fgHaSchedule Load-balancing schedule of the cluster (in Active-Active mode).
1.3.6.1.4.1.12356.101.13.1.7 fgHaGroupName HA cluster group name.

Nach oben ↑

Aruba

1.3.6.1.4.1.14823

Aruba Networks MIBs: AP table, SSID stats, client association, radio utilization

Für diesen Teilbaum liefert die MIB des Herstellers die Namen: in SNMP Explorer importieren, dann zeigt der Walk sie an.